1. Your hands are numb when driving.

When the vehicle is traveling at a speed higher than mid-speed, the chassis has periodic sounds. In severe cases, the cab and doors tremble, and the steering wheel vibrates strongly until the hand is numbed. This is due to the fact that the dynamic balance of the steering gear is damaged, the transmission shaft and its splines. Shaft and spline over wear.

When the vehicle is traveling at a speed higher than mid-speed, the chassis has periodic sounds. In severe cases, the cab and doors tremble, and the steering wheel vibrates strongly until the hand is numbed. This is due to the fact that the dynamic balance of the steering gear is damaged, the transmission shaft and its splines. Shaft and spline over wear. How to identify the steering wheel failure

2. Heavy and laborious steering.

The reasons are due to the fact that the rolling bearings and sliding bearings in various parts of the steering system are over-tightened, the bearings are not well lubricated, and the ball ends of the steering trailing rods and tie rods are tightened too tightly or lack of oil, and the steering shaft and casing are bent, resulting in jamming; Inadequate adjustment of toe; pre-sprung or frame bending deformation; insufficient tire pressure, especially front tires.

3. The steering wheel is difficult to manipulate.

When driving or braking, the direction of the vehicle is automatically biased toward the side of the road. In order to ensure straight-line driving, the steering wheel must be firmly held. The causes of vehicle deviation are: the specifications of the front wheels on both sides or the air pressure are inconsistent, and the front wheels or the camber angles on both sides are not equal, and the front wheels and bearings on both sides are The gap is inconsistent. The steel plate springs on both sides do not have the same degree of camber or elasticity. The wheelbase between the left and right sides has a large difference, the wheel brake gap is too small or the brake drum is out of round, causing the side brake to issue a card, causing the brake to stick and the vehicle to load unevenly. Wait.

4. The direction of hair floating.

Often caused by driving the front wheel swing, when the vehicle reaches a certain high speed, there are reasons for the steering wheel to shiver or swing: shimming the tire or tire repair caused the balance of the front wheel assembly is destroyed, the total drive shaft Parts become loose, the dynamic balance of the drive shaft assembly is destroyed, the shock absorber fails, the rigidity of the leaf spring is inconsistent, the wear of the steering system parts is loose, and the front wheels are improperly aligned.


Metal Body Square Water Cooling Tower

This series of products run stable, low noise, energy-saving, in office buildings, shopping malls, hotels, residential areas and other central air-conditioning supporting the use of better results.

The company's standard cooling tower according to the international design conditions design, can also provide customers with non-standard operating conditions or specific sizes under the special, special design.

The circulating water pump suction port shall be located below the water level of the cooling tower catchment basin, and the cooling tower outlet pipe shall not be allowed to be higher than the maximum water level of the catchment basin.
Pipe mounts should be pipe racks and cooling towers should not be allowed to directly bear the weight of the pipes.

The rehydration pipe of the cooling tower should be provided with a support stand to avoid vibration of the pipe when the float valve is rehydrated.

Rehydration pressure should be below 5m water pressure, national standard
The flannage pressure is 1.0Mpa.

When two or more units are assembled, our company will provide a connecting balance tube to balance the chassis water level. The tower top inlet should be set with a conditioning valve in order to enter each
.The water level of the tower is uniform.


The noise is measured at dm1.13VL-W at the equivalent diameter of the cooling tower (Dm1.13VL*W), 1.5 meters above the ground height, wherein L and W are the shape rulers of the tower
inch long and wide).

The use of cellular continuous blister series of diversion,heat dissipation, water collection three-in-one native filler, the whole suspension, gravity cloth water, low drop of water, with cold effect
High, low energy consumption, less drift water, less noise and so on, floating water rate is less than 0.001%.

When connecting different types of towers, the bottom basin water level height of different types of towers must be taken into account, and the base height must be adjusted to maintain the water level balance of the towers.

Metal Body Square Water Cooling Tower,Tower Water Cooler,Water Cooled Cooling Tower,Tower Cooling System

Wuxi Ark Fluid Science Technology Co., Ltd. , https://www.arkfluid.com