Ai Sirong temperature and humidity test chamber operation precautions

    First , to check whether the power is stable before turning on the power.

    Second , in order to prevent electric shock or malfunction and failure, please do not turn on the power until the installation and wiring are completed.

   Third , in order to avoid machine failure in the constant temperature and humidity test chamber, please provide power within the rated voltage range.

    4. The constant temperature and humidity test chamber is non-explosive, so it cannot be used in a bad environment with flammable or explosive gas.

    5. When the constant temperature and humidity test box is running, please try not to open the door. If it is opened at high temperature, it may cause scalding to the operator. Opening it at low temperature may cause frostbite to the staff, and may cause the evaporator to freeze and affect the cooling effect. If you must open, please do a good job of protection.

The Seven Elements of Aster's Constant Temperature and Humidity Test Chamber

A: The air vents of the airframe must be kept unobstructed to avoid malfunctions, abnormal movements, reduced life expectancy, and fire.

If you find the machine is damaged or deformed when you open the box, do not use it.

Second, when installing the equipment, be careful not to allow dust, thread, iron filings or other things to enter, otherwise it will malfunction or malfunction.

Third, the wiring must be correct, must be grounded. Ungrounded may cause electric shock, malfunction, abnormal display, or measurement error.

Fourth, check the terminal screws and holders regularly. Do not use them loosely.

5. During the operation of the instrument, the power input terminal cover must be installed on the terminal board to prevent electric shock.

6. Use a dry cloth to wipe the meter. Do not use alcohol, gasoline, or other organic solvents. Do not splash water on the meter. If the meter is immersed in water, stop using it immediately. Otherwise, there is a danger of electric leakage, electric shock, or fire.

VII. Before the instrument is in operation, before modifying the settings, signal output, starting, stopping, etc., the safety shall be fully considered. The wrong operation will cause the working equipment to be damaged or malfunction.