Polymer Concrete Cells For ER/EW Processing Of Nonferrous
Long-term impermeability, free of corrosion, 20+ years warranty
The structural core of electrolytic cells is bolstered with sturdy external seismic reinforcement blocks confining its floor supports, and includes a robust, internal bidirectional, pultruded FRP bar mesh reinforcement which positively maintains integrity should the cell fail due to catastrophic events. Electrolytic cell installation protocols call for lateral wall collaboration between cells,thus reducing stress levels of cell around 40% under normal operating conditions.
Polymer Concrete Electrolytic Cell,Electrolytic Cell Nickle,Electrolytic Cell Nickle Refining Tanks,Electrolytic Cells of Electroplating Equipment Hebei aoliande Chemical Equipment Co., Ltd , https://www.aoliandechemical.com
Applacation:
It applies to delivering non-corrosive lubricating-oil or equivalent liquid without solid particles and fibres at temperature below 80 deg C and with the viscosity of 5-1500cSt. It applies to hydraulicSystem, too.
Applacation Scope:
It can give performance as transferpump or booster pump in oil delivery system, and a fuel pump for delivery, pressurization and injectiion in fuel supply system. It can be also applied as hydraulic pump suplying hydraulic power in hydraulic system and in all industy fields as lubricating pump.
Structure Features:
YCB series gear pumps are mainly composed of gears, axles, pump body, pump cap, bearing sleeves and axle-end seals, etc. The gears are adoped double circular teech shape, which makes the gears less wear on gear surface, stable revolution, low noise, long service life and high efficiency, due to on sliding on the teeth during gear falling-in. This kind of pump has got rid of traditonal design and come into a new decade in designing and application.
The pump is designed with safety valve for protection against overload. The full return flow pressure is 1.5times higher than the rated exhaust pressure of the pump. It can be adjusted within the allowance of exhaust pressure range according to Circumstance. But please note the safety valve can't be applied as presusure-reducing valve for long time. You may install pressure-reducing valve separately on pipe-line if needed.
There are two kinds of axle-end seals, mechanical seal and packing seal, which can be chosen according to the clients' requirement or application circumstance.
Technical parameter:
Flow: 0.6m3/h~80m3/h
Pressure: 0.6Mpa~2.5Mpa
Speed: 970rpm~2900rpm
Dia of inlet & outlet: 25mm~150mm
Model
Capacity
Speed
r/minExhaust
Pressure
Mpa(NPSH)r
mEfficiency
η %Motor
m 3 /h
Hz
Power
kwModel
YCB0.6-0.6
0.6
910
0.6
5.5
32
50
0.75
Y90S-6
1.0
1390
50
0.75
Y80L2-4
0.7
1130
60
0.75
Y90S-6
1.2
1710
60
0.75
Y80L2-4
YCB0.6-2.5
0.6
910
2.5
7.0
70
50
1.1
Y90L-6
1.0
1400
50
1.5
Y90L-4
0.7
1130
60
1.1
Y90L-6
1.2
1710
60
1.1
Y90S-4
YCB1.6-0.6
1.6
910
0.6
5.5
42
50
0.75
Y90S-6
2.5
1400
50
1.1
Y90S-4
1.9
1130
60
1.1
Y90L-6
3.0
1710
60
1.5
Y90L-4
YCB1.6-2.5
1.6
940
2.5
7.0
71
50
2.2
Y112M-6
2.5
1440
50
4
Y112M-4
1.9
1150
60
2.2
Y112M-6
3.0
1750
60
4
Y112M-4
YCB3.3-0.6
3.3
940
0.6
5.0
60
50
1.5
Y100L-6
5.0
1420
50
2.2
Y100L1-4
4.0
1150
60
1.5
Y100L-6
6.0
1730
60
2.2
Y100L1-4
YCB3.3-2.5
3.3
960
2.5
7.0
72
50
5.5
Y132M2-6
5.0
1440
50
7.5
Y132M-4
4.0
1170
60
4
Y132M1-6
6.0
1750
60
7.5
Y132M-4
YCB4-0.6
4.0
940
0.6
5.0
60
50
1.5
Y100L-6
6.0
1420
50
2.2
Y100L1-4
4.8
1150
60
2.2
Y112M-6
7.2
1730
60
3
Y100L2-4
YCB4-2.5
4.0
960
2.5
7.0
72
50
5.5
Y132M2-6
6.0
1440
50
7.5
Y132M-4
4.8
1170
60
5.5
Y132M-6
7.2
1750
60
7.5
Y132M-4
YCB8-0.6
8.0
960
0.6
5.0
61
50
3
Y132S-6
12.0
1440
50
5.5
Y132S-4
9.6
1170
60
4
Y132M1-6
14.4
1750
60
5.5
Y132S-4
YCB8-2.5
8.0
970
2.5
7.0
75
50
11
Y160L-6
12.0
1460
50
15
Y160L-4
9.6
1170
60
11
Y160L-6
14.4
1760
60
15
Y160L-4
YCB10-0.6
10.0
960
0.6
5.0
62
50
4
Y132M1-6
15.0
1440
50
5.5
Y132S-4
12.0
1170
60
5.5
Y132M2-6
18.0
1750
60
7.5
Y132M-4
YCB10-2.5
10.0
970
2.5
7.0
76
50
11
Y160L-6
15.0
1470
50
15
Y160L-4
12.0
1170
60
11
Y160L-6
18.0
1770
60
18.5
Y180M-4
YCB20-0.6
20.0
970
0.6
5.0
68
50
7.5
Y160M-6
24.0
1170
60
7.5
Y160M-6
YCB25-0.6
25.0
970
0.6
5.5
69
50
11
Y160L-6
30.0
1170
60
11
Y160L-6
YCB30-0.6
30.0
970
0.6
5.5
70
50
11
Y160L-6
36.0
1170
60
11
Y160L-6
YCB40-0.6
40.0
970
0.6
5.5
72
50
15
Y180L-6
48.0
1180
60
15
Y180L-6
YCB50-0.6
50.0
970
0.6
5.5
72
50
22
Y200L2-6
60.0
1180
60
22
Y200L2-6
YCB60-0.6
60.0
1470
0.6
5.5
72
50
22
Y180L-4
YCB80-0.6
80.0
980
0.6
5.5
72
50
30
Y205M-6
Electrolytic cells are designed, built and installed to satisfy the most stringent requirements requested by tankhouse operators worldwide. In most cases their main request is to guarantee full operating availability throughout the plant's lifespan, maximizing production of high-purity metal (copper, zinc, nickel, cobalt, lead or other nonferrous metals) with absolute safety for people and the environment. Additionally, cells must accommodate changes for continuous improvement of the electrolytic process, integrating efficiently with upgrades of complementary equipment such as anodes, cathodes, cap, boards, overhead crane electrolyte agitation systems, acid mist control devices, thermal insulation among many others.
The Internal layer is a monolithic tank made with multiple layers of fiber-reinforced vinyl ester resin (FRP) complying with chemical barrier international norms that assure long-term impermeability and corrosion resistance.
The Intermediate layer is the structural core made with polymer Concrete, with a patented formulation to achieve a low coefficient of thermal expansion, providing long-term structural integrity with low thermally-induced stresses
The External layer is a standard seal layer of FRP that further protects the structural core from electrolyte splashes and spills. Optionally,this external seal may be specified with multi-layered oriented fiber reinforcements to guarantee trouble-free operation in unusually extreme operating environments.
Benefits of electrolytic cells
Our monolithic internal tank manufactured with multiple layers of fiber-reinforced premium vinyl ester resin. It has continuous service without leakage, free of corrosion and structural flaws which operating under normal conditions as specified for each project.
Swift, accurate and less costly installation
Electrolytic cells include features that allow reduction of 25% or more in time needed for cell erection, alignment and leveling compared to time required with conventional polymer concrete cells. Dimension tolerances for electrolytic cells are consistently tight, simplifying installation in the most demanding applications,including plants with automated crane systems.
Minimum cleaning time and water consumption
The rounded internal shape,optional sloped cell floors,and smooth,flat finish of the internal tank,facilitate water sweeping and drainage of heavy sludge,with reduced water usage and accelerating return to service after each cleaning.
Minimum maintenance cost
The robust, virtually impervious internal tank that is chemically bound to the polymer concrete structural core during molding is tolerant to operating abuse its smooth,non-stick surfaces minimize adhesion of contaminants.
Maximum operational safety
Model NO.: YCB80
Noise: Low
Service Life: Long
Trademark: HENGNUO
Transport Package: Marine Wooden Case
Specification: ISO: 9001-2000; CE
Origin: Cangzhou
HS Code: 8413602990
2. Structure
Electrolytic cells are cast monolithically based on a patented, three-layer composite material system: